Discover the care behind a battery system. Explore Z1’s planned 5 kWh assembly process—from traceable cells and precision connections to testing and quality review.
30,000sq ft total150 × 200ft footprint32ft building height4H2 Plus robots
Dedicated Battery and Inverter areas form the heart of our planned Mead facility. Each has its own component flow, assembly stations, testing and quality release, supported by a shared engineering and customer-facing office area.
OfficesAssembly / testingInverter areaBattery materialsH2 support bay
Discover each production area.
office / gross zone allowance
Reception
30 × 30 ft · 900 sq ft
A proposed welcome space for visitors, product conversations and controlled entry to the production areas.
office / gross zone allowance
Offices
30 × 30 ft · 900 sq ft
A shared office area supporting customer relationships, administration and plant coordination.
office / gross zone allowance
Engineering
30 × 30 ft · 900 sq ft
A dedicated workspace for product engineering and production planning, close to both plant areas.
office / gross zone allowance
Meeting / QA
30 × 30 ft · 900 sq ft
A shared space for project discussions, technical reviews and quality documentation.
office / gross zone allowance
Staff / services
30 × 30 ft · 900 sq ft
Staff facilities and building services supporting the people behind the production process.
inverter / gross zone allowance
Inverter receiving
58 × 28 ft · 1,624 sq ft
Dedicated inverter component receiving, inventory and incoming inspection, separate from battery materials.
inverter / gross zone allowance
Inverter assembly
58 × 48 ft · 2,784 sq ft
The proposed inverter assembly area brings electronics, power-stage integration, controlled fastening and firmware checks together.
inverter / gross zone allowance
Inverter test
58 × 30 ft · 1,740 sq ft
A dedicated inverter testing area with product-specific electrical and functional checks.
inverter / gross zone allowance
Inverter dispatch
58 × 28 ft · 1,624 sq ft
Inverter quality review, packing and finished-goods staging, with a separate product history.
logistics / gross zone allowance
Battery receiving
58 × 28 ft · 1,624 sq ft
Battery materials begin their journey here, with supplier identity, incoming inspection and controlled storage.
line / gross zone allowance
Cell screening
58 × 22 ft · 1,276 sq ft
Calibrated cell screening and compatible build-set preparation before battery assembly.
line / gross zone allowance
Stack / connect
58 × 28 ft · 1,624 sq ft
Precision cell placement, mechanical support and product-specific connection checks form the core of the planned assembly area.
line / gross zone allowance
Cabinet / BMS
58 × 22 ft · 1,276 sq ft
The battery enclosure, management electronics and harness come together before inspection and closure.
test / gross zone allowance
Battery test
26 × 28 ft · 728 sq ft
Dedicated battery electrical testing and monitored cycling support a documented quality review.
logistics / gross zone allowance
Battery dispatch
26 × 28 ft · 728 sq ft
Battery quality release, label verification and supported packing complete the planned production flow.
4,500 sq ft offices + 25,500 sq ft factory
A proposed balance of customer, engineering and production space. Areas include circulation and are shown as a concept layout.
Our proposed shared building keeps Battery and Inverter production physically separate, with dedicated materials, testing and quality review for each program. This schematic illustrates our manufacturing vision; final layout and equipment are subject to engineering and commissioning.
H2-01
Battery receiving
Planned support for empty trays and light material kits near battery receiving.
H2-02
Battery components
Planned staging of lightweight assembly kits at dedicated battery handoff areas.
H2-03
Inverter supplies
Planned support for lightweight component kits near inverter assembly.
H2-04
Inverter packing
Planned staging of labels and accessory trays near inverter packing.
OUR PLANNED ASSEMBLY PROCESS
AI-generated process visualization. Equipment, cell layout and robot tasks are proposed; this is not footage of an operating Z1 factory. Chapter time is film time, not production cycle time.
THE MATERIAL PATH12 QUALITY GATES
Quality before releaseThe planned process holds any product that does not meet its acceptance criteria for review and reinspection before release.
01 / 12
Receive & identify
Our planned battery assembly begins with finished supplier cells. The receiving process links their identity and supplier lot to the production record.
Quality focus
Cell identity, supplier documentation and visible condition.
Traceability
Supplier lot and incoming inspection history.
Why it matters
A clear origin for the components inside each system.
02 / 12
Screen the cells
Cell screening is designed to assess electrical condition before assembly, using calibrated equipment and product-specific acceptance criteria.
Quality focus
Voltage, resistance and the required inspection results.
Traceability
Screening results and equipment calibration references.
Why it matters
Early checks help keep unsuitable cells out of an assembly.
03 / 12
Match a build set
Compatible cells are allocated to a battery build, creating a link between individual components and the finished system.
Quality focus
Cell compatibility, count, chemistry and orientation.
Traceability
Cell identities linked to the planned battery serial number.
Why it matters
A documented component history for each battery.
04 / 12
Prepare insulation
Dielectric barriers and support components form part of the battery’s internal protection. The planned process checks their placement before the next assembly step.
Quality focus
Insulation condition, correct parts and placement.
Traceability
Design revision and inspection evidence.
Why it matters
Attention to the details that separate and protect internal components.
05 / 12
Locate & restrain
Dedicated fixtures support precise cell placement and restraint within the assembly. The final arrangement will follow product-specific design requirements.
Quality focus
Cell orientation, alignment and mechanical support.
Traceability
Assembly revision and component orientation checks.
Why it matters
Repeatable positioning throughout the build.
06 / 12
Make the connections
Cell connections bring the assembly together electrically. Our planned approach pairs product-specific joining methods with documented connection checks.
Quality focus
Polarity and connection quality against product-specific design requirements.
Traceability
Joining process revision and inspection results.
Why it matters
Verified connections at a critical point in the battery build.
07 / 12
Integrate the enclosure
The supported battery assembly is integrated with its cabinet, with attention to retention, insulation and cable routing.
Quality focus
Mechanical fit, clearances and protected routing.
Traceability
Enclosure and component lot history.
Why it matters
A coordinated mechanical and electrical assembly.
08 / 12
Install BMS & harness
The battery management system, sensors and protection components connect the cells to the system’s monitoring functions.
Quality focus
Harness mapping, connectors and firmware revision.
Traceability
BMS identity, firmware and harness inspection.
Why it matters
A documented check of the battery’s monitoring and protection components.
09 / 12
Inspect & close
Inspection before closure checks the internal assembly, cable routing and covers. Additional enclosure checks depend on the product specification.
Quality focus
Routing, barriers, closure and applicable enclosure checks.
Traceability
Closure inspection and any required enclosure test results.
Why it matters
A final review of the assembly before electrical testing.
10 / 12
End-of-line checks
A dedicated test station is planned for the required electrical and functional checks, including battery management signals and communications.
Quality focus
Electrical and functional results against product acceptance criteria.
Traceability
Battery test report and calibrated equipment references.
Why it matters
Documented verification before quality review.
11 / 12
Cycle & observe
The proposed test flow includes controlled charge and discharge observation, with temperature and battery management behavior reviewed against the product test plan.
Quality focus
Performance and observation criteria for the battery system.
Traceability
Cycling results and thermal observations.
Why it matters
An additional view of system behavior beyond assembly inspection.
12 / 12
Release & dispatch
Quality review brings component history, inspection evidence and test results together before labeling, packing and dispatch.
Quality focus
Complete inspection records and authorized quality release.
Traceability
Final battery serial number and release documentation.
Why it matters
A connected production history behind the finished system.
Precision with purpose
RIGHT TASK. RIGHT MACHINE.
01 / HUMANOID ASSIST
H2 Plus
Four H2 Plus robots are part of our proposed support team: two for each plant. Their planned roles center on light component kits, trays and assisted material staging.
02 / PRECISION & LOAD
Fixed arms & fixtures
Our planned precision stations combine fixed arms, dedicated fixtures and controlled tools for repeatable placement and fastening. The film illustrates the approach; final equipment is still being engineered.
03 / PROCESS AUTHORITY
Engineering & quality
Engineering, production and quality teams remain central to our approach. Automation supports repeatability, while documented inspections and quality review guide product release.
A vision for consistent quality.
Our product reference is the Z1Power 5 kWh wall-mounted battery: 51.2 V, 100 Ah and lithium iron phosphate (LiFePO₄) chemistry.
The planned assembly flow starts with finished supplier cells and brings them together with the enclosure, battery management system and protection components.
Component identity, connection checks and electrical testing form the core of the proposed quality approach.
Battery and Inverter programs have dedicated production and test areas within the same proposed facility.
The facility and automation shown here are a planning concept, not a commissioned production line. This visualization does not establish product certification or measured manufacturing performance.